TECMEN Freflow Filters.

5 variants
  • Quick Ship
Replacement filters for TECMEN FreFlow respirator High level respirator protection - Certificate to AS / NZS 1716:2012(Sai Global) EN12941 TH3 P R SL. Pre-Filter Used to filter large particles & to extend the life of the P3 Main filter.(come as a pack of 5). P3 Main Particle Filter For Highest level of welding, dust, and grinding particle protection, P3 main filter provides 99.97% particle. Odour filter Is an optional extra for the Freflow PAPR respirator system. This ia a charcoal filter layer is recommended to help to reduce nuisance odours. ABEK1 Gas filter An optional extra filter to be used to protect against vapours & gases class1 (A1B1E1K1).

Replacement filters for TECMEN FreFlow respirator High level respirator protection - Certificate to AS/NZS 1716:2012(Sai Global) EN12941 TH3 P R SL Pre-Filter Used to filter large particles & to extend the life of the P3 Main filter.(come as a pack of 5) P3 Main Particle Filter For Highest level of welding, dust, and grinding particle protection, P3 main filter provides 99.97% particle, compliant to AS/NZS 1716:2012.

The Main Particle filter is used in conjunction with a Pre-Filter*.

Odour filter Is an optional extra for the Freflow PAPR respirator system.

Charcoal filter layer is recommended to help to reduce nuisance odours during cutting, burning, welding applications.

The Odour filter is also used in conjunction with a Pre-Filter & Particle filter*.

Replace any time you can smell odours while wearing the respirator.

Available in a complete unit with holder and filter(Need to start with this), and replacement ongoing filters ABEK1 Gas filter An optional extra filter to be used to protect against vapours & gases class1 (A1B1E1K1).

Filter type A = Certain organic vapours such as cyclohexane (boiling point above 65°C) from solvents such as those in paints and thinners.

Filter type B = Acid gases such as chlorine, hydrogen sulfide (sulphide) and sulfur dioxide.

Filter type E = Vapours from sulfur dioxide.

Filter type K = ammonia gas.

The gas filter is also used in conjunction with a Pre-Filter & Particle filter*.

Replace filter any time you can smell odours while wearing the respirator. *Refer to Filter setup diagram for more connection details.

Customers also bought

Need Help?

No worries. Reach us via ...
sales@euromarc.co.nz
Online now (8am - 5pm)

TECMEN Freflow Filters. Variants - Add to Cart

or Register to see your price & quantities

Image
Description
Specs
Availability
Features & Alerts
Price / Bulk Discount
Add to Cart
WSHWR95020
Pack Size5 Pack
PartPre-Filter
Pack Size5 Pack
PartPre-Filter
In Stock
  • Quick Ship
    Eligible for QuickShip™. Order before the daily cutoff time for faster dispatch from our warehouse.
Unit (1) $31.01 ea
WSHWR95022
Pack Size1 Pack
PartParticle Filter (P3)
Pack Size1 Pack
PartParticle Filter (P3)
In Stock
  • Quick Ship
    Eligible for QuickShip™. Order before the daily cutoff time for faster dispatch from our warehouse.
Unit (1) $47.21 ea
WSHWR95025
Pack Size1 Pack
PartABEK-1 filter
Pack Size1 Pack
PartABEK-1 filter
In Stock
  • Quick Ship
    Eligible for QuickShip™. Order before the daily cutoff time for faster dispatch from our warehouse.
Unit (1) $212.47 ea
WSHWR95021
Pack Size1 Pack
PartOdour Filter
Pack Size1 Pack
PartOdour Filter
In Stock
Unit (1) $72.81 ea
WSHWR95031
Pack Size1 Pack
PartOdour Holder & Filter
Pack Size1 Pack
PartOdour Holder & Filter
In Stock
Unit (1) $128.77 ea

Additional Information

Replacement filters for TECMEN FreFlow respirator High level respirator protection - Certificate to AS/NZS 1716:2012(Sai Global) EN12941 TH3 P R SL Pre-Filter Used to filter large particles & to extend the life of the P3 Main filter.(come as a pack of 5) P3 Main Particle Filter For Highest level of welding, dust, and grinding particle protection, P3 main filter provides 99.97% particle, compliant to AS/NZS 1716:2012.

The Main Particle filter is used in conjunction with a Pre-Filter*.

Odour filter Is an optional extra for the Freflow PAPR respirator system.

Charcoal filter layer is recommended to help to reduce nuisance odours during cutting, burning, welding applications.

The Odour filter is also used in conjunction with a Pre-Filter & Particle filter*.

Replace any time you can smell odours while wearing the respirator.

Available in a complete unit with holder and filter(Need to start with this), and replacement ongoing filters ABEK1 Gas filter An optional extra filter to be used to protect against vapours & gases class1 (A1B1E1K1).

Filter type A = Certain organic vapours such as cyclohexane (boiling point above 65°C) from solvents such as those in paints and thinners.

Filter type B = Acid gases such as chlorine, hydrogen sulfide (sulphide) and sulfur dioxide.

Filter type E = Vapours from sulfur dioxide.

Filter type K = ammonia gas.

The gas filter is also used in conjunction with a Pre-Filter & Particle filter*.

Replace filter any time you can smell odours while wearing the respirator. *Refer to Filter setup diagram for more connection details.

Save to QuickOrder

Access Restricted

Cart

Go to Cart

No products in the cart.